AHU Repair & Service in Jakarta

The AHU is a building's lungs: every breath the occupants take passes through its coils, filters and fans. We still regularly find AHUs whose filters have not been changed in over a year — airflow down 30%, stuffy floors, and compressors working far harder than they should.

Unit down right now? Message an engineer

We repair and service AHUs and FCUs in office towers, malls, hotels, hospitals, factories and warehouses across Greater Jakarta: fault diagnosis and part replacement when a unit fails, and scheduled maintenance contracts so it does not fail again. On every visit we measure actual airflow (CFM) and filter pressure drop — not just "it has been cleaned" — because numbers are the only proof an AHU is back at design performance.

Technician servicing an air handling unit in a commercial building plant room

Common AHU faults we fix (motor, bearing, belt, coil leak, VFD trip)

Most AHU breakdowns we are called to fall into five groups:

  • Motor & bearings — motors overheating or burning out after long overload, worn fan bearings that vibrate and grind. We measure current and vibration first, then decide between a bearing change and a motor rewind or replacement.
  • Loose, cracked or broken belts — a worn drive lowers fan RPM and airflow drops sharply even though the motor sounds normal.
  • Leaking or frozen coils — a refrigerant leak cuts cooling capacity, while a frosted coil usually points to blocked airflow or low refrigerant pressure.
  • Heavily clogged filters — dust and grease push the pressure drop far above normal, forcing the fan to work harder and raising the building's power bill.
  • Controls & VFD/inverter faults — repeated trips, error codes, faulty temperature or pressure sensors, and VFD programs that need a reset or full reprogramming.

Contract clients get 24/7 emergency priority. Non-contract clients are served Monday–Saturday 08:00–17:00 WIB; for critical conditions such as a burning smell, smoke or a major water leak we aim for a same-day visit across Greater Jakarta. Send photos or a video of the fault on WhatsApp so we can prepare likely spare parts before leaving.

AHU repair costs

  • Diagnostic visit and minor repairs (belt, contactor, sensor) — from IDR 1.8 million/unit.
  • Bearing replacement and motor service — priced per condition after current and vibration readings.
  • Replacement coil (fabricated to size) — typically IDR 15–60 million depending on dimensions and rows.
  • New VFD/inverter — from IDR 8 million/unit including programming.
  • Emergency call-out outside a contract (assessment + first repair) — from IDR 2.5 million/visit, excluding parts.

Scheduled AHU maintenance: scope of work

  • Routine maintenance — chemical coil cleaning, filter replacement (pre, medium, HEPA), blower and drain-pan cleaning.
  • Mechanical & electrical repair — fan bearings, belts, motors, contactors, temperature sensors and damper actuators.
  • Air balancing — measuring and adjusting CFM per zone to restore design air distribution.
  • Coil replacement — replacement coils fabricated to the old unit's dimensions and BTU capacity.
  • Energy retrofits — VSD/inverter installation, IE3 motor upgrades, casing insulation repair.

Maintenance cost estimate

Baseline rates for AHU work in Jakarta, 2026:

  • Routine AHU service (chemical coil clean + filters + mechanical checks) — from IDR 1.8 million/unit.
  • Building maintenance contract (AHU + FCU) — from IDR 3.5 million/month depending on unit count.
  • Coil replacement — typically IDR 15–60 million depending on dimensions and rows.
  • VSD installation — from IDR 8 million/unit including programming.

A written BoQ is free after the survey.

How we work

The workflow is identical on every project, from a shop-house to a factory — so you always know exactly where things stand:

  1. Site survey (free) — we visit, measure the area, check installation routes, electrical capacity and structure. In factories we also note the production processes that drive heat loads.
  2. BoQ & working drawings — within 2–5 working days you receive a written bill of quantity, material specifications and drawings. The price we quote is the price we invoice.
  3. Installation — K3- and BNSP-certified crews work to the agreed schedule, including nights and weekends when production cannot stop.
  4. Testing & commissioning — airflow, temperature and electrical readings are documented in a commissioning report, followed by handover with a written 12-month warranty.

AHU servicing is most efficient bundled into one contract with the chillers and cooling towers — one team, one logsheet, one party responsible for the whole plant room. We serve buildings across Central and South Jakarta and all of Greater Jakarta; for new air-side systems see ducting installation.

Discuss on WhatsApp

AHU Repair & Service — Common Questions

How often should AHU filters be changed?
Pre-filters every 1–3 months, medium filters every 3–6 months, HEPA every 6–12 months — based on measured pressure drop. We fit simple manometers so building engineers can monitor it themselves.
Why is airflow weak even though the fan runs?
Usual suspects: loaded filters, a fouled coil, a slipping belt, or dampers that have drifted out of position. An on-site CFM measurement pinpoints the restriction immediately.
Can you service AHUs outside office hours?
Yes — most building AHU work is scheduled at night or on weekends, unit by unit, so cooling is never fully interrupted.
Do you handle hospital and cleanroom AHUs?
Yes, including HEPA replacement and particle-count verification. For isolation and operating rooms we follow the applicable room-pressure protocols.

Send a Nameplate Photo or Plant Layout → First Estimate the Same Day

Free site survey and written BoQ across Greater Jakarta and Karawang. K3 & BNSP-certified team, in-house duct fabrication, 12-month written warranty on installation work.